TECANYL
TECANYL®, due to its inherent chemical composition, exhibits unusually low moisture absorption. Therefore, good electrical insulating properties are realized over a wide range of humidity and temperature conditions. Chemical attack from water, most salt solutions, acids and bases is also minimal with TECANYL®. The addition of glass fiber reinforcement enhances both the mechanical and thermal properties of the basic TECANYL® material. Made from Noryl® EN265 resin.
- Good electrical insulating properties
Due to its extremely low water absorption with values as low as 0.07%, TECANYL® is an excellent electrical insulating material. - Long-term dimensional stability
- Superior impact strength
TECANYL® has a notched Izod impact strength of 3.5 ft-lbs/in. - TECANYL® exhibits a continuous use temperature in excess of 220°F
- Wide range of UL flammability ratings from
UL94 HB to UL94 V-1 - FDA compliance for certain grades
- Light weight
TECANYL®, with a density of 0.0383 lbs/in3, can be used in applications where weight is a significant consideration. - Thermoformable capability
- Possesses good hydrolytic stability
Made from Noryl EN265 resin® exhibits a broad range of outstanding properties for applications in computers and business equipment, automotive, electrical insulation, telecommunications, appliances, electronics, and many other industries.
| Properties | ASTM Test Method | Units | TECANYL® | |
|---|---|---|---|---|
| Physical |
Density
|
D792 | lbs/in3 | 0.0383 |
|
Specific Gravity
|
D792 | - | 1.08 | |
|
Water Absorption, @ 24 hours, 73°F
|
D570 | % | 0.07 | |
|
@ Saturation, 73°F
|
- | - | - | |
| Mechanical |
Tensile Strength @ Break, 73°F
|
D638 | psi | 9,200 |
|
Tensile Modulus, 73°F
|
D638 | psi | 3.5 X 105 | |
|
Elongation @ Break, 73°F
|
D638 | % | 25 | |
|
Flexural Strength, 73°F
|
D790 | psi | 13,400 | |
|
Flexural Modulus, 73°F
|
D790 | psi | 3.7 X 105 | |
|
Compressive Strength
|
D695 | psi | - | |
|
Izod Impact Strength, Notched, 73°F
|
D256 | ft-lbs/in | 3.5 | |
|
Rockwell Hardness, 73°F
|
D785 | "R" Scale | 119 | |
|
Shore Hardness
|
- | - | - | |
|
Wear Factor Against Steel, 40 psi, 50 fpm
|
- | - | - | |
|
Static Coefficient of Friction
|
- | - | 0.32 | |
|
Dynamic Coefficient of Friction, 40 psi, 50 fpm
|
- | - | 0.39 | |
| Thermal |
Heat Deflection Temperature @ 66 psi
|
D648 | °F | 279 |
|
@ 264 psi
|
D648 | °F | 254 | |
|
Coefficient of Linear Thermal Expansion
|
D696 | in/in/°F | 3.3 x 10-5 | |
|
Maximum Servicing Temperature, Intermittent
|
- | °F | 230 | |
|
Long Term
|
- | °F | 220 | |
|
Specific Heat
|
- | - | - | |
|
Thermal Conductivity
|
- | - | - | |
|
Vicat Softening Point
|
- | °F | 310 | |
|
Applicable Temperature Range for Thermal Expansion
|
- | °F | 0-140 | |
|
Flammability
|
UL94 | - | V-1 | |
| Electrical |
Surface Resistivity
|
- | - | - |
|
Volume Resistivity, 73°F
|
D257 | ohm-cm | 1 x 1017 | |
|
Dielectric Strength
|
D149 | V/mil | 500 | |
|
Dielectric Constant, @ 60 Hz, 73°F, 50% RH
|
D150 | - | 2.7 | |
|
Dissipation Factor, @ 60 HZ, 73°F
|
D150 | - | 0.0007 | |
| This information is only to assist and advise you on current technical knowledge and is given without obligation or liability. All trade and patent rights should be observed. All rights reserved. NORYL®-General Electric Company. |
||||